Contents:

back to main page

σ 24,25 ER78
σ 24,23 ER78 SH11
σ 24,26 ER78
σ 24,22 ER78
σ 24,27 ER78
σ 24,21 ER78

Xe 24+ + Ar → Xe 25+

Table 1 (Experiment)

B. Erb // GSI Rep. P-7-78 (1978)

E, MeV/amu σ 24,25 , 10 -16 cm 2
1.39 1.12

Error does not exceed 9 %

Xe 24+ + Ar → Xe 23+

Table 2 (Experiment)

B. Erb // GSI Rep. P-7-78 (1978)

E, MeV/amu σ 24,23 , 10 -16 cm 2
1.39 0.108

Error does not exceed 15 %

Table 3 (Theory, OBK with normalization at low energy)

V.P. Shevelko, I.L. Beigman, M.S. Litsarev, H. Tawara, I. Yu. Tolstikhina, G. Weber //Nucl. Instr. Methods Phys. Res. B V. 269, P.1455 (2011)

E , MeV/amu

σ 24,23 , 10 -16 cm 2
0.01 110.0
0.02 100.0
0.03 90.0
0.05 75.0
0.07 61.0
0.1 45.0
0.2 24.0
0.3 17.0
0.5 10.0
0.7 7.5
1.0 4.9
2.0 1.9
3.0 1.0
5.0 0.34
7.0 0.19
10.0 0.049
20.0 6.3e-3
30.0 1.3e-3
50.0 1.4e-4
70.0 2.2e-5
100.0 2.9e-6
120.0 1.0e-6

Xe 24+ + Ar → Xe 26+

Table 4 (Experiment)

B. Erb // GSI Rep. P-7-78 (1978)

E, MeV/amu σ 24,26 , 10 -16 cm 2
1.39 0.186

Error does not exceed 13 %

Xe 24+ + Ar → Xe 22+

Table 5 (Experiment)

B. Erb // GSI Rep. P-7-78 (1978)

E, MeV/amu σ 24,22 , 10 -16 cm 2
1.39 0.0704

Error does not exceed 22 %

Xe 24+ + Ar → Xe 27+

Table 6 (Experiment)

B. Erb // GSI Rep. P-7-78 (1978)

E, MeV/amu σ 24,27 , 10 -16 cm 2
1.39 0.0336

Error does not exceed 11 %

Xe 24+ + Ar → Xe 21+

Table 7 (Experiment)

B. Erb // GSI Rep. P-7-78 (1978)

E, MeV/amu σ 24,21 , 10 -16 cm 2
1.39 0.0401

Error does not exceed 27 %