Contents:

back to main page

σ 7,6 MU77 KU86
σ 7,5 MU77
σ 7,4 MU77
σ 7,3 MU77

Xe 7+ + Kr → Xe 6+

Table 1 (Experiment)

A. Muller, E.Salzborn // Phys.Let. A v.62 p.391 (1977)

E, MeV/amu E, MeV σ 7,6 , 10 -16 cm 2
0.000229 0.030 100.

Not indicated error does not exceed 30 %

Table 2 (Experiment)

T. Kusakabe, T. Horiuchi, N. Nagai, H. Hanaki, I. Konomi, M. Sakisaka // J. Phys. B v.19 p.2165 (1986)

E , MeV/amu

σ 7,6 , 10 -16 cm 2
0.000286 55.0

Error does not exceed 13 %

Xe 7+ + Kr → Xe 5+

Table 3 (Experiment)

A. Muller, E.Salzborn // Phys.Let. A v.62 p.391 (1977)

E, MeV/amu E, MeV σ 7,5 , 10 -16 cm 2
0.000229 0.030 33.

Not indicated error does not exceed 30 %

Xe 7+ + Kr → Xe 4+

Table 4 (Experiment)

A. Muller, E.Salzborn // Phys.Let. A v.62 p.391 (1977)

E, MeV/amu E, MeV σ 7,4 , 10 -16 cm 2
0.000229 0.030 20.

Not indicated error does not exceed 30 %

Xe 7+ + Kr → Xe 3+

Table 5 (Experiment)

A. Muller, E.Salzborn // Phys.Let. A v.62 p.391 (1977)

E, MeV/amu E, MeV σ 7,3 , 10 -16 cm 2
0.000229 0.030 3.5

Not indicated error does not exceed 30 %